Essay · April 17, 2026

# Room Based BIM IV

- **Author**: Clifton Harness
- **Date**: April 17, 2026
- **Address**: /harness-architecture/room-based-bim-iii

For dwelling-unit rooms covered by 2023 NEC 210.52(A), receptacles serve qualifying wall spaces so no point along the floor line is more than 6 ft from a receptacle in that space. This study follows that distance around corners and treats door openings as breaks. Move a door and watch the outlets follow: a small shift can change how many the room needs.

Interactive study Doors break the wall space; the outlets follow

Example basis: [2023 NEC · dwelling-unit wall-space example (Minnesota DLI, item 016) ↗](https://www.dli.mn.gov/sites/default/files/pdf/eli_inspection_checklist2023NEC.pdf#page=2)

The model counts continuous wall spaces of 2 ft or more and assumes doors in otherwise plain walls. Other interruptions and special-room provisions are outside its scope. Door-leaf exclusion zones and 6 in offsets from corners and jambs are layout preferences that may be relaxed to maintain coverage, not NEC requirements or a physical swing-clearance check. A project still depends on its adopted edition and local amendments. Example basis: [Minnesota DLI’s 2023 NEC inspection checklist, item 016](https://www.dli.mn.gov/sites/default/files/pdf/eli_inspection_checklist2023NEC.pdf#page=2).

## Revision history

- **November 2, 2026**: Corrected the receptacle-spacing explanation and stated the dwelling-unit scope, source and model limits.

End of essay · Clifton Harness · April 17, 2026