Play an illustrative day of household electricity use or step through five preset views: the original five loads, an everything-on interval, EV charging, an electrified home and six homes sharing a transformer. The drawings compare connected ratings and assumed simultaneous use with service-rating reference lines and code-calculation examples.
The first example contains 6 kW of general load, a 12 kW range, a 5 kW dryer, 4 kW of cooling and a 4.5 kW water heater: 31.5 kW connected. That sum does not select a service rating.
Appliance ratings and operating schedules are fixed examples, not editable inputs for your home. The calculation comparisons use the study’s stated assumptions and cited methods; they do not select a service or panel for a particular installation. An electrical design needs the applicable calculation method, actual nameplate data and installation conditions.